November 17, 2026

EU MDR Transition Deadlines: 2027 and 2028 Explained for Legacy Devices

Short answer: Medical devices still sold in the EU under old Directive certificates can stay on the market until 31 December 2027 (Class III and Class IIb implantable devices) or 31 December 2028 (all other affected classes), but only if the manufacturer met specific conditions in 2024. After those dates, the device needs an EU MDR certificate to continue being placed on the market.

The EU Medical Device Regulation (MDR) has applied since 26 May 2021. Because notified bodies could not certify every device in time, the EU extended the transition period in 2023. That extension has given manufacturers breathing room, but the first deadline is now only around a year away.

What is a legacy device?

A legacy device is one that is still placed on the EU market under a certificate issued under the old Medical Devices Directive (MDD) or Active Implantable Medical Devices Directive (AIMDD), rather than under the MDR. These devices can continue to be sold during the transition period, as long as the conditions are met.

The EU MDR transition deadlines

  • Class III devices: 31 December 2027
  • Class IIb implantable devices (except some, such as sutures, staples, dental fillings and screws, which follow the 2028 date): 31 December 2027
  • Other Class IIb devices: 31 December 2028
  • Class IIa devices: 31 December 2028
  • Class I sterile or measuring devices: 31 December 2028
  • Devices up-classified under MDR that were self-declared Class I under the MDD: 31 December 2028

Custom-made Class III implantable devices had an earlier deadline of 26 May 2026, which has now passed.

The conditions you must meet

The extended dates only apply if all of these are true:

  1. The device still complies with the old Directive.
  2. There have been no significant changes to the design or intended purpose since the old certificate was issued.
  3. The device does not present an unacceptable risk to health or safety.
  4. You had an MDR quality management system in place by 26 May 2024.
  5. You lodged a formal application with a notified body for MDR certification by 26 May 2024.
  6. You signed a written agreement with that notified body by 26 September 2024.

You must also meet MDR requirements on post-market surveillance, market surveillance, vigilance and registration in the meantime.

If any of these conditions is missing, the extension may not apply and your old certificate may already have expired. That is worth checking now, with evidence on file.

What about IVDs?

The In Vitro Diagnostic Regulation (IVDR) has its own extended, staggered timeline for legacy IVDs:

  • Class D: 31 December 2027
  • Class C: 31 December 2028
  • Class B and sterile Class A: 31 December 2029

Similar conditions apply, including a quality management system and applications to a notified body by set dates. See our EU IVD services for support.

Why "a year away" is not long

An MDR certification project typically takes 12 to 18 months, and sometimes longer. It usually involves:

  • Notified body review of technical documentation
  • Quality management system and technical audits
  • Rounds of questions, often focused on clinical evidence
  • Corrective actions and resubmissions
  • Issue of the certificate

If your notified body has not yet started reviewing your file, you are already tight for a December 2027 deadline. Notified body capacity has improved, but queues remain, especially for higher-risk devices.

Will the EU MDR revision change the deadlines?

The European Commission proposed a targeted revision of the MDR and IVDR in December 2025, and it is moving through the European Parliament and Council. It includes useful changes, such as removing the automatic five-year expiry of certificates. But it is not law yet, and it is unlikely to be in force in time to change the 2027 deadline. Plan as if the current dates will stand.

What happens if you miss the deadline?

If a legacy device does not have an MDR certificate by its deadline, it can no longer be placed on the EU market. Devices already placed on the market before the deadline can generally continue to be made available, but you will not be able to supply new stock. For many companies this means losing a key product line in the EU, and in Northern Ireland, which follows EU rules.

What should you do now?

  1. List every legacy device with its class and deadline.
  2. Check each condition above and file the evidence: QMS certificate, notified body application and signed agreement.
  3. Ask your notified body for a realistic timeline, in writing, and agree milestones.
  4. Prioritise high-risk devices with the December 2027 deadline.
  5. Strengthen clinical evidence early. It is the most common cause of delay.
  6. Have a plan B for any device that will not make it, such as a phased withdrawal or a different market.

Frequently asked questions

When does the EU MDR transition period end?

For Class III and Class IIb implantable legacy devices, 31 December 2027. For other Class IIb, Class IIa, Class I sterile and measuring devices, and up-classified devices, 31 December 2028.

What conditions apply to the MDR transition extension?

The device must still comply with the Directive, have no significant changes and pose no unacceptable risk. The manufacturer must have had an MDR QMS and a formal notified body application by 26 May 2024, and a signed notified body agreement by 26 September 2024.

Can I still sell legacy devices in Great Britain?

Great Britain has its own rules. Devices certified under the old Directives are expected to be recognised in line with the EU timelines. Our guide on selling CE marked devices in Great Britain explains more.

Will the MDR revision extend the deadlines?

The revision proposal does not currently extend the 2027 and 2028 dates, and it is not yet law. Manufacturers should plan to meet the existing deadlines.

How Taylored Consultancy can help

We support manufacturers through MDR transition, from gap analysis and technical documentation to clinical evaluation, notified body liaison and quality management systems. Explore our EU medical device services and ISO 13485 support, or contact us to talk through your transition plan.

‍

Need expert help? Not sure where to start?

Get in touch